22

Hampton

®

H15-1 Direct Vent Freestanding Gas Stove

Dura-Vent Basic

Horizontal Kit # 970

1 90

o

Elbow

1 Wall

Thimble

Cover

1 Horiz.

Sq.

Term.

Cap

DURA-VENT TERMINATION KIT

Planning Your Dura-Vent

Installation

There are two basic types of Dura-Vent Direct
Vent System installations: horizontal termination
and vertical termination. Confi rm the maximum
horizontal run and maximum vertical rise from
the diagrams in the "Rigid Pipe Venting Sys-
tems" section.

When planning your installation, it will be nec-
essary to select the proper length of vent pipe
for your particular requirements. For horizontal
installations, determine the minimum clearance
from the rear of the unit to the wall. It is also

important to note the wall thickness. (The
wall thimble is suitable for 2 x 4 or 2 x 6 wall
construction.) Select the amount of vertical
rise desired for "vertical-to-horizontal" type
installations.

Warning: Always maintain required
clearances (air spaces) to nearby
combustibles to prevent a fire
hazard. Do not fi ll air spaces with
insulation.

The minimum clearance requirements between
the outer wall of the vent pipe and nearby com-
bustible surfaces is 1-1/4 inch. Be sure to check

the vent termination clearance requirements
from decks, windows, soffi ts, gas regulators, air
supply inlets and public walkways as specifi ed
in the "Exterior Vent Terminal Locations" section
and in your local building codes.

To determine the length of vent pipe required
for vertical installations, measure the distance
from the unit fl ue outlet to the ceiling, the ceiling
thickness, the vertical rise in an attic or second
storey, and allow for suffi cient vertical height
above the roof line.

For multi-storey applications, fi re stops are
required at each fl oor level. If an offset is
needed, additional pipe, elbows and supports
will be required.

Do not exceed the maximum number of elbows.
One 90

o

for horizontal terminations and two 45

o

for vertical termination.

AstroCap

Part# 946-523/P

Alternate Horizontal

Termination Caps

Alternate
Horizontal
Riser Vent
Terminal
Part# 640-530/P

The FPI AstroCap

TM

is certifi ed for installations using FPI venting systems

as well as Simpson Dura-Vent® and Direct Vent GS.

The FPI AstroCap

TM

is a proprietary trademark of FPI Fireplace Prod-

ucts International Ltd.

Dura-Vent® and Direct Vent GS are registered and/or proprietary
trademarks of Simpson Dura-Vent Co. Inc.