Test and adjustment, Specifications – Heath Zenith CB-2010 User Manual

Page 3

Advertising
background image

Page 3

Motion

Motion

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE:

Sensor has a 1

2

minute warm up period

before it will detect motion. When first turned
on or when switching modes wait 1

2

minutes.

Bottom of Sensor

Avoid aiming the sensor at:

Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

Areas where pets or traffic may trigger the con-

trol.

Nearby large, light-colored objects reflecting

light may trigger the shut-off feature. Do not point
other lights at the sensor.

Maximum Range

8 ft.

(2.4 m)

Maximum

Coverage Angle

70 ft.

100 ft.

(21 m) (30.5 m)

Boosted

Least Sensitive

Most Sensitive

Sensor

The detector is less sensitive to motion directly
towards it.

Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor.

Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cov-
erage area. Keep the sensor
at least 1" (2.5 cm) away
from the lamps
.

Adjust the RANGE as
needed. RANGE set too high
may increase false triggering.

Secure the sensor head's
aim by tightening the clamp
screw.
Do not overtighten
the screw.

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5 or 20 minutes).

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.

(30.5 m) with Range Boost.
[varies with surrounding
temperature]

Sensing Angle . . . . . . Up to 200

°

Electrical Load . . . . . . 300 watt Incandescent [150 W

each lamp holder].

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . 1 , 5, 20 minutes

Heath/Zenith reserves the right to discontinue products and to
change specifications at any time without incurring any obligation
to incorporate new features in products previously sold.

200

°

Turn the RANGE control to the mid position and
the ON-TIME control to the TEST position.