Error Messages

130

Embedded Web Server User Guide

Error 152: Invalid FICON

Management Server State

The request cannot be

completed because the

FICON MS state

submitted is invalid.

The FICON MS state may

be set to either enable or

disable.

Error 153: Feature Key

Not Installed

The request cannot be

completed because the

required feature key has

not been installed to the

firmware.

Contact your sales

representative.

Error 154: Invalid

Membership List WWN

The request cannot be

completed because the

WWN does not exist in

the switch binding

membership list.

Make sure that the WWN

deleted matches the

WWN in the switch

membership list. Make

appropriate changes and

resubmit the request.

Error 155: Cannot

Remove Active Member

From List

This member cannot be

removed from the fabric

security list because it is

currently logged in.

Fabric security rules

prohibit any device or

switch from being isolated

from the fabric via a

membership list change. If

it is truly the intention of

the user to remove the

device in question from

the membership list, then

there are several

approaches to take. This

request may be

completed most

non-disruptively by

blocking the port (or

physically removing the

device from the managed

switch) to which this

device is attached and

resubmitting the request.

Error 156: Cannot

Disable Fabric Binding

while Switch is Online

The switch must be offline

and fabric binding must

be inactive before this

feature can be disabled.

Deactivating this feature

can be disruptive to

Fabric operations. Take

the switch offline and

deactivate fabric binding

before disabling this

feature.

Table 9: Embedded Web Serve Messages (Continued)

Message

Description

Action

Advertising