HP AA-RTDRB-TE User Manual

Page 132

Advertising
background image

Error Messages

132

Embedded Web Server User Guide

Error 211: Duplicate

Zone

Two or more zone names

in the local zone set are

identical.

All zone names must be

unique. Make the

appropriate changes and

resubmit.

Error 212: Duplicate Zone

Member

A member was added

that already exists in the

zone.

No action necessary.

Error 213: Number of

Zones Is Zero

You are attempting to

activate and empty zone

set.

The zone set must have at

least one zone to be

considered valid. Add a

valid zone to the zone set

and resubmit.

Error 214: A Zone

Contains Zero Members

You are attempting to

activate a zone set that

contains at least one zone

with zero members.

Each zone in the zone set

must contain at least one

member. Add a valid

member to the empty

zone and resubmit.

Error 215: Zone Set Size

Exceeded

The local work area zone

set has outgrown the size

limitations imposed by the

Command Line Interface.

Reduce the size of the

zone set to meet CLI

requirements. This can be

a reduction in the number

of zones in the zone set, a

reduction of members in a

zone, or a reduction of

zone name lengths.

Error 218: Invalid Port

Number

The value entered for the

port number is invalid

Enter a port number

within the range

supported by your

director or switch. Valid

values are:
0-15 for the

Edge Switch 2/16
0-23 for the

Edge Switch 2/24
0–31 for the

Edge Switch 2/32
0–63 for the

Director 2/64
0–127 and 132–143 for

the Director 2/140

Table 9: Embedded Web Serve Messages (Continued)

Message

Description

Action

Advertising