Dry Seasoned Wood Only!

TL2.0 Woodburning Stove

Save These Instructions

3-90-08560

Chimney Breach Fireplace Conversion with Combustible Wall

Minimum Clearance from

Chimney Connector to Un-

protected Ceiling

Flue Liner with Required Air Space

Listed or Approved Thimble Assembly

1" Clearance for Complex-

ity Exterior Chimney

or

2" Clearance for Interior

Chimney and 2" Clear-

ance for NFPA 211-Type

Approved Thimbles

* Floor Protection in Accordance with Solid Fuel Appliance Listing

** Check with your local building codes for clearance.

Combustible

Wall

Sheetrock

Airtight

insulated

Clean-out

Combustible Floor

Damper Closed and
Sealed with Non-
Combustible
Material.

Floor Protection*

16"**

The Chimney Connector shall Not Pass Through an attic or Roof space, Closet or similar

Concealed space, a floor or Ceiling.