About alc, Alc module types, About x-10 – Home Automation HOME AUTOMATION User Manual

Page 27: House codes

Advertising
background image

When set to RadioRA, the Omni IIe controller can:

¾

Send commands (on, off, and level) to individual Switches and Dimmers

¾

Receive status (on and off) from individual Switches and Dimmers

¾

Receive commands when buttons are pressed on Master Controls

¾

Execute Phantom Button commands


About ALC


ALC is intended for installation in homes, which have been pre-wired for installation of ALC system products. Omni IIe controls
lights and appliances by sending commands over the ALC signal wiring to ALC Switch Modules. ALC Switches communicate
with the Omni IIe over low voltage signal wire. They are two-way devices, so the controller always knows the actual status of the
switch. In addition, ALC switches can be used to set scenes by triggering macros in Omni IIe.

When ALC Lighting Control Modules are being used, it is also possible to "ramp" the lighting level of an ALC Dimmer Switch to
a new level at a controllable ramp rate.

ALC Module Types

The ALC modules types are: Dimmer Switch, Relay Switch, Slave Switch, Program Switch, and 4-Button Scene Switch Modules.


About X-10


The Omni IIe controls lights and appliances by sending commands over your existing electrical wiring to special switches,
outlets, receptacles, and modules, collectively referred to as X-10. Each module (or group of modules) is assigned a House Code
and a Unit Number so that the Omni IIe can control the modules individually. When a module hears a command from the Omni
IIe for its house code and unit number, it executes the command.

There are 3 different X-10 formats: Standard X-10 (Preset Dim), Extended X-10 (Extended Level), and Compose.

Any module that is "X-10 Compatible" will work with the Omni IIe. The modules come in various types.

House Codes


Omni IIe can control up to 64 lighting and appliance devices. Each device (switches, modules, and keypad) has its own Unit
Number (1-64). Omni IIe groups devices by “House Code”, which consists of 16 consecutive unit numbers, starting at Unit 1.
Each “House Code” can be configured to a different lighting protocol format such as: Standard X-10, Extended X-10, Lightolier
Compose, UPB (open UPB format where you can use the programming capability in the Omni IIe controller to communicate with
the UPB network), Lutron RadioRA, CentraLite, or HAI Lighting Control (HLC).

Different lighting devices can not share the same House Code. However, different lighting devices can coexist on an Omni IIe
system as long as they are on separate House Codes. For example:

House Code 1 (Units 1-16) = HLC
House Code 2 (Units 17-32) = UPB
House Code 3 (Units 33-48) = X-10 Extended
House Code 4 (Units 49-64) = CentraLite

Page 19

Advertising
This manual is related to the following products: