Entry Lights
0=OFF 1=ON 2=DIM 3=BRT

Entry Lights
4=LVL 5=RMP 9=TIM #=STA

¾ Press 0 (OFF) to turn the selected unit off.

¾ Press 1 (ON) to turn the selected unit on.

¾ 2 (DIM) does not affect CentraLite units.

¾ 3 (BRT) does not affect CentraLite units.

¾ Press 4 (LVL) to set the desired lighting level of the selected unit (0%-100%).

¾ 5 (RMP) does not affect CentraLite units.

¾ Press 9 (TIM) to time the selected unit (On or Off). Timed commands may be from 1-99 seconds, 1-99 minutes or 1-18

hours.

¾ Press # (STA) to see the status (On or Off) of a CentraLite device.

Controlling RadioRA Units

Entry Lights
0=OFF 1=ON 2=DIM 3=BRT

Entry Lights

4=LVL 5=RMP 9=TIM #=STA

¾ Press 0 (OFF) to turn the selected unit off

¾ Press 1 (ON) to turn the selected unit on.

¾ 2 (DIM) does not affect RadioRA units.

¾ 3 (BRT) does not affect RadioRA units.

¾ Press 4 (LVL) to set the desired lighting level of the selected unit (0%-100%).

¾ 5 (RMP) does not affect RadioRA units.

¾ Press 9 (TIM) to time the selected unit (On or Off). Timed commands may be from 1-99 seconds, 1-99 minutes or 1-18

hours.

¾ Press # (STA) to see the status (On or Off) of a RadioRA device.


Note: When a RadioRA device transmits a signal (i.e. Switch or Dimmer is turned on or off locally, Mater Control button is
pressed, or Phantom Button is executed), Omni IIe will automatically update the status of each affected device.


Controlling ALC or X-10 Units

Entry

Lights

0=OFF

1=ON

2=DIM

3=BRT

Entry

Lights

4=LVL

5=RMP

9=TIM

#=STA