When a counter is decremented to zero, the "When Unit Off" macro is executed. A counter will not decrement below zero. The
counter will, however, roll over from 255 to 0 when incremented. The "When Unit Off" macro will be executed when the counter
rolls over. This allows two counters to be cascaded to form a larger counter.

When the counter is incremented from 0 to 1, the "When Unit On" macro will now execute. This will allow you to execute a
command when the Flag is incremented (counting up) from zero.

The Set command is used to set the counter to a value from 0 to 255. No macros are executed when the counter is set to zero or
when the counter is changed from zero using the set command. This allows a counter to be reset without executing macros or
programs associated with the counter counting to zero. Turn the Flag On or Off to have the associated macro execute. When the
Flag is turned Off, its value is set to zero (0). When the Flag is turned On, its value is set to one (1). The counter is considered
On for program conditions if it is nonzero (1-255).

Flags can be turned Off, On, Decremented (DEC), Incremented (INC), Set, and Timed ON/OFF.

Controlling Outputs


The Omni IIe has eight outputs that can be used to switch relays. Outputs 1-8 are controlled as Unit Numbers 65-72, respectively.
If the Interior Horn is configured as a "General Purpose" output, Unit Number 73 is used to control the output. If the Exterior
Horn is configured as a "General Purpose" output, Unit Number 74 is used to control the output. In this configuration, Unit
Numbers 73 and 74 should not be used as "Flags".

These 12 VDC voltage outputs are connected directly to the Omni IIe and not through a module. If you have something
connected to these outputs, such as a sprinkler system, your dealer will explain its operation.

Outputs cannot be brightened or dimmed and are not affected by All ON or All Off commands.


All On / Off


The All On/Off menu is used to turn all unit numbers in the specified House Codes on and off.

Note: UPB, CentraLite, and RadioRA devices are not affected by the Omni IIe “All On” or “All Off” command. To achieve this
functionality, we suggest the following:

UPB: Program a Link into each device that will respond to an Omni IIe “All On” and “All Off” command program. For
example:

In each UPB switch that will respond to “All Off” and “All On”, program a Link (in this example, Link 50 is used) that
will go to 100% when activated (turned on). Then write the following programs in the Omni IIe controller:

WHEN ALL ON: LINK 50 ON

WHEN ALL OFF: LINK 50 OFF


CentraLite: Program the “All On” and “All Off” macro to execute an All On Scene and an All Off Scene on the
CentraLite.

RadioRA: Program the “All On” and “All Off” macro to execute Phantom Button 16 (All On) and Phantom button 17 (All Off).

For example:

WHEN ALL ON: PHANTOM BUTTON 16 ON
WHEN ALL OFF: PHANTOM BUTTON 17 ON


This All On/Off menu is also used to control Leviton Scenes, RadioRA Phantom Buttons, UPB Links, and CentraLite Scenes.

From the top-level display or from the main menu, press the 4 (ALL) key on the console keypad.