Henny Penny 600 EN User Manual

Page 4

Advertising
background image

Model 500/561/600

Fig.

Item

Description

Function

No.

No.

3-2

16

Safety Relief Valve

This is an ASME approved spring loaded valve, set at 14.5 psi; if
the deadweight assembly is clogged, this safety valve releases
excess pressure, keeping the frypot chamber at 14.5 psi
(999 mbar); if this occurs, turn the main power switch to OFF to
release all pressure from the frypot

3-2

17

Safety Relief Valve Ring

DO NOT PULL THIS RING. SEVERE BURNS FROM

THE STEAM WILL RESULT.

3-2

18

Pressure Gauge

Indicates the pressure inside the frypot

3-5

3-2

19

Solenoid Valve

An electromechanical device that causes pressure to be held in the
frypot; the solenoid valve closes at the beginning of the Cook Cycle
and is opened automatically by the controls at the end of the Cook
Cycle; if this valve becomes dirty or the teflon seat nicked, pressure
will not build up and it must be repaired

3-3

20

Drain Valve (Only the

A two-way ball valve that is normally close; turn the handle to drain

Handle is Shown)

the shortening from the frypot, into the filter drain pan

DO NOT OPEN THE DRAIN VALVE WHILE FRYPOT
IS UNDER PRESSURE. HOT SHORTENING WILL
EXHAUST AND SEVERE BURNS WILL RESULT.

3-3

21

Drain Interlock Switch

A microswitch that provides protection for the frypot in the event an
operator inadvertently drains the shortening from the frypot while
the main power switch is on; the switch automatically shuts off the
heat when the drain valve is opened

3-4

608

3-1. OPERATING COMPONENTS

(Continued)

If safety relief valve activates, turn main power switch
to the OFF position. To avoid serious burns and
injuries, have fryer serviced before next use.