SECTION 3 − SPECIFICATIONS

3-1. Specifications

Rated Welding

Output

Maximum

Amperage

Maximum Open-

Circuit Voltage

DC

Amperes Input at

Rated Load Output

115 V, 60 Hz, Single-

Phase

KVA

KW

Weight

W/ Gun

Overall

Dimensions

90 A @ 19 Volts DC,

20% Duty Cycle

63 A @ 21 Volts DC,

20% Duty Cycle*

125

29

20

15*

2.90

2.20*

2.50

1.77*

50 lb

(22.7 kg)

Length: 16-7/8 in

(429 mm)

Width: 9-7/8 in

(251 mm)

Height: 12-1/8 in

(308 mm)

Wire Type

And Dia

Flux Cored

Wire Feed Speed Range

.030 − .035 in

(0.8 − 0.9 mm)

183 − 295 IPM (4.6 − 7.5 m/min) At No Load

112 − 236 IPM (2.8 − 6.0 m/min) Feeding Wire

* CSA Rating

3-2. Duty Cycle And Overheating

Duty Cycle is percentage of 10 min-

utes that unit can weld at rated load

without overheating.
If unit overheats, thermostat(s)

opens, output stops, and cooling

fan runs. Wait fifteen minutes for

unit to cool. Reduce amperage or

duty cycle before welding.
NOTICE − Exceeding duty cycle

can damage unit or gun and void

warranty.

Overheating

0

15

A or V

OR

Reduce Duty Cycle

Minutes

duty1 4/95 − 210 517-A

20% duty cycle at 90 amps

2 Minutes Welding

8 Minutes Resting

1

4

20

40

60

100

2

6

8

10

20

40

60

80

100

200

135

10

Duty Cycle %

Output Amperes