Installation, Wiring – Heath Zenith Motion Sensing Diecast Lantern HB-4190 Series User Manual

Page 2

Advertising
background image

2

595-5770-05

INSTALLATION

For best performance, mount the fixture about
1.8 meters above the ground.

1. Remove

two nuts.

2. Remove

X-Bar.

Junction

Box

5. Attach X-Bar to

junction box

Due to the size and weight of the fixture, you
may find it helpful to have an assistant hold the
fixture in place while connecting the wires.

WIRING

One Motion Light

BLACK

WHITE

Two Motion Lights

BLACK

BLACK

WHITE

Recommended Grounding Method

Use a green ground “pigtail” (not provided) and
twist one end together with the bare fixture wire
and the box ground wire. Secure with a wire
connector. Secure the other end of the “pigtail”
with the GND screw on the X-Bar.

Black to black

MAX

MIN

4. Set sensitivity on

fixture back to the
mid-position.

3. Tighten screws

finger tight.

SENSITIVITY

WARNING: Turn power off at circuit

breaker.

WHITE

Twist the junction box wires and the
fixture wires together as shown below.
Secure with wire connectors. If you have
a metal junction box, you may not need
the green “pigtail”. If you are unsure about
the grounding method, consult your local
building code.

CAUTION: DO NOT connect the RED wire

unless you want to control other lights from
the motion sensor.

White to white

Advertising