Caution – Honeywell PROTECTORELAY R8184G User Manual

Page 3

Advertising
background image

3

69-0617—1

CHECK CAD CELL

1. Disconnect power at system switch, circuit breaker or

fuse.

2. Clean cell face with soft cloth.
3. Make sure cell is seated securely in socket. Be careful

not to disturb socket position.

4. Reconnect cad cell leads to F-F terminals.
5. Reset safety switch, turn on power and set thermostat

TRIP SAFETY SWITCH BEFORE PERFORMING
BURNER MAINTENANCE

CAUTION

Tripping the safety switch shuts down the burner but
does not disconnect the power supply. Turn off power
at system switch or circuit breaker before servicing
the control system, burner motor, oil valve or ignition
to avoid electric shock.

To trip the safety switch, move the safety switch lever

down until the red reset button pops out and the indicator
light comes on. See Fig. 5. Burner will not operate until
safety switch is reset by pushing in the red reset button.

Fig. 4—Move lever down to trip safety switch.

PUSH LEVER DOWN
TO TRIP SAFETY SWITCH

WHEN SAFETY SWITCH TRIPS

INDICATOR LIGHT COMES ON
(TRADELINE ONLY)

RESET BUTTON POPS OUT

M17882

Advertising