Corrective Maintenance



CHANGING THE HEATING ELEMENTS

1. Disconnect power source and empty oven of flux.

2. Remove element cover and leads from elements (Note: power cord strain relief may have to be

removed to gain clearance.)

3. From interior of oven, remove elements from clips and pull elements free of hopper wall.

4. Replace new elements and electrical leads being sure terminals are not shorted to oven body. Replace

element cover.




CHANGING THE THERMOSTAT

1. Disconnect from the power source.

2. Remove element cover (Note: power cord strain relief may have to be removed to gain clearance).

3. Remove electrical leads from thermostat and remove thermostat from mounting bolt.

4.

Replace and rewire new thermostat being sure terminals are not shorted to oven body. Do not over

tighten elements mounting bolt.




















KF –100A 120V / 500W
Wiring Diagram

KF –100A 240V / 500W
Wiring Diagram