Heat & Glo Fireplace TIARAP-CES User Manual

Page 11

Advertising
background image

August 1, 2008

Page 11

Heat & Glo · Tiara Petite B · 7026-101K

25'

24'

22'

20'

18'

16'

14'

12'

10'

8'

6'

4'

2'

6 in. (152mm) Minimum starter pipe

30 in. (762mm) Maximum Horizontal run with no vertical pipe and with 1/4 in.
(6mm) rise per foot. Must use approved Termination Cap.

C

L

25 ft. (8m)

Maximum Vertical

2' 4' 6' 8' 10' 12' 14' 15'

Termination cap

Termination cap

Example 1

Example 2

Adjust
Intake

Damper

SLK-01TRD or an approved Termination Cap

6 ft. (2m) Minimum
Vertical Termination

VERTICAL DISTANCE
FROM APPLIANCE TO
90° ELBOW

Install Flue

Restrictor

Adjust
Intake

Damper

D.

How to Use the Vent Graph

E.

Venting Guidelines

1

. Measure the distance from the top of appliance to the

center of the 90° elbow. On the graph below, draw a
horizontal line from that measurement on the vertical
axis across until it intersects with the slanted line.

2. From the point of this intersection, draw a vertical line to

the bottom of the graph.

3. The point at which this line meets the bottom line of the

graph is the maximum length of the horizontal run.

Example 1: If the vertical dimension from the top of the
appliance to the center of the 90° elbow is 7 ft. (2m), the
horizontal run to the outer wall fl ange must not exceed 9
ft.-8 in. (3m).

.

Example 2: If the vertical dimension from the top of the
appliance is 21 ft. (6m), the horizontal run to the outer wall
fl ange must not exceed 4 ft.-3 in. (1m).

4. Each 90° elbow is equivalent to 3 ft. (914mm) of vent

pipe and each 45° elbow is equivalent to 1 ft. (305mm)
of vent pipe, and must be subtracted from vent pipe
run. A single vertical to horizontal 90° elbow is already
calculated into the allowable 15 ft. (5m) run. Each
additional 90° elbow reduces the maximum horizontal
distance by 3 ft. (914mm).

Example: The use of three elbows would reduce the

allowable horizontal run to 9 ft. (3 - 1 = 2 elbows
x 3 ft. = 6 ft.; 15 ft. max. - 6 ft. = 9 ft. max.)

Notes:
• The maximum horizontal vent run is 15 ft. (5m) when the

vertical vent rise is 10 ft. (3m).

• Horizontal sections require a 1/4 in. (6mm) rise for every

12 in. (305mm) of horizontal travel.

• Exterior vent diameter = 6-5/8 in. (168mm); Inner vent

diameter = 4 in. (102mm).

• Horizontal sections require noncombustible support every

3 ft. (914mm) , e.g. wall straps.

• For any vertical termination a minimum of 6 ft. (2m)

vertical must be used.

EXCEPTIONS FOR HORIZONTAL INSTALLATIONS:

*The maximum horizontal vent run is 30 in. (762mm).

*The maximum horizontal vent run with a 45° elbow is
18 in. (457mm).

*No external minimum rise is required.

*The minimum horizontal vent run is 6 in. (152mm).

Figure 5.2

NOTE: In the Commonwealth of Mas-
sachusetts the word damper shall be
replaced with the words fl ue restrictor.