14 installation, Changing to natural gas – Harman Stove Company Conquest Gas Stove User Manual

Page 14

Advertising
background image

14

INSTALLATION

Only For Qualified Installers

Changing to Natural Gas

Remove pilot tower with
a 7/16” wrench. Replace
LP orifice with Natural
Gas orifice. See
instructions in kit.

Use a 1/2” deep well
socket to remove the LP
#53 orifice and replace
with the #37 Natural gas
orifice from the kit.

Natural Gas Kit

Part No. 1-00-09112

NG Conversion label

NG Orifice #37

NG Valve
Conversion
Module

NG Conversion
Instructions

This kit is only for use in the Conquest direct
vent gas stove.

Natural Gas Conversion Kit

NG Pilot Orifice

Remove the three screws that hold the
LP knob module in place. Remove the
module and replace with the Natural
gas module from the kit. See kit
instructions.

Remove four
bolts and
remove burner
module from
stove.

3

1

2

4