Hearth and Home Technologies IDV4833ILH User Manual

Page 14

Advertising
background image

Heatilator • ICON DV-IDV Series • 4042-575 • Rev K • 11/08

14

Control Compartment and Firebox Top

Frequency: Annually

By: Qualifi ed Service Technician

Tools needed: Protective gloves, vacuum cleaner, dust
cloths
• Vacuum and wipe out dust, cobwebs, debris or pet hair.

Use caution when cleaning these areas. Screw tips that
have penetrated the sheet metal are sharp and should
be avoided.

• Remove all foreign objects.
• Verify unobstructed air circulation.

Figure 3.1 IPI Pilot Flame Patterns

B. Maintenance Tasks-Qualifi ed Service
Technician

The following tasks must be performed by a qualifi ed
service technician.

Logs

Frequency: Annually

By: Qualifi ed Service Technician

Tools needed: Protective gloves.
• Inspect for damaged or missing logs. Replace as

necessary. Refer to Section 14.H. for log placement
instructions.

• Verify correct log placement and no fl ame impingement

causing sooting. Correct as necessary.

Firebox

Frequency: Annually

By: Qualifi ed Service Technician

Tools needed: Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.
• Inspect for paint condition, warped surfaces, corrosion

or perforation. Sand and repaint as necessary.

• Replace

fi replace if fi rebox has been perforated.

Gasket Seal and Glass Assembly Inspection

Frequency: Annually

By: Qualifi ed Service Technician

Tools needed: Protective gloves, drop cloth and a stable
work surface.
• Inspect gasket seal and its condition.
• Inspect

fi xed glass assembly for scratches and nicks

that can lead to breakage when exposed to heat.

• Confi rm there is no damage to glass or glass frame.

Replace as necessary.

• Verify

that

fi xed glass assembly is properly retained and

attachment components are intact and not damaged.
Replace as necessary.

Burner Ignition and Operation

Frequency: Annually

By: Qualifi ed Service Technician

Tools needed: Protective gloves, vacuum cleaner, whisk
broom, fl ashlight, voltmeter, indexed drill bit set, and a
manometer.
• Verify burner is properly secured and aligned with pilot

or igniter.

• Clean off burner top, inspect for plugged ports, corrosion

or deterioration. Replace burner if necessary.

• Replace rockwool with new dime-size pieces. DO NOT

block ports or obstruct lighting paths. Refer to Section
14.I for proper rockwool placement.

• Verify batteries have been removed from battery back-

up IPI systems to prevent premature battery failure or
leaking.

• Check for smooth lighting and ignition carryover to all

ports. Verify that there is no ignition delay.

• Inspect for lifting or other fl ame problems.
• Verify air shutter setting is correct. See Section 14.M.

for required air shutter setting. Verify air shutter is clear
of dust and debris.

• Inspect

orifi ce for soot, dirt and corrosion. Verify orifi ce

size is correct. See Service Parts List for proper orifi ce
sizing.

• Verify manifold and inlet pressures. Adjust regulator as

required.

• Inspect

pilot

fl ame pattern and strength. See Figure 3.1

for proper pilot fl ame pattern. Clean or replace orifi ce
spud as necessary.

• Inspect thermocouple/thermopile or IPI fl ame sensing

rod for soot, corrosion and deterioration. Clean with
emery cloth or replace as required.

• Verify thermocouple/thermopile or IPI millivolt output.

Replace as necessary.