19

Measured from top of fireplace opening (in inches)

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

11-1/2

12-1/4

13

13-3/4

14-1/2

15-1/4

16

16-3/4

17-1/2

18-1/4

19

19-3/4

20-1/2

21-1/4

22

22-3/4

30 in. minimum

to ceiling

1

2

10

10-3/4

D. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).

Figure 5.3 Minimum Vertical and Maximum Horizontal Dimensions

1 in. (25 mm) min.
to perpendicular wall

A

7.75 in. (159 mm) min.
from fireplace opening
to perpendicular wall

B

Mantel Leg or

Perpendicular Wall

Top of
Appliance

Drywall

A

B

Figure 5.4 Mantel Leg or Wall Projections (Acceptable on both sides of opening)

Mantels