SPECIFICATIONS

Range . . . . . . . . . . . . . Up to 60 ft. (18.3 m); [varies

with surrounding temperature]

Sensing Angle . . . . . . . Up to 110

°

Electrical Load . . . . . . . Up to 300 Watts Maximum

Tungsten

Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . . 1, 5 or 10 minutes
Sensitivity . . . . . . . . . . Adjustable
Replacement lamp . . . T 300W (or less) halogen 120

VAC

DESA Specialty Products™ reserves the right to dis-
continue products and to change specifications at any
time without incurring any obligation to incorporate new
features in products previously sold.

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

Maximum

Range

110

°

Maximum

Coverage Angle

NOTE: Sensor requires about 1

1

/

2

minutes to calibrate

before it will detect motion. When first turned
on, wait about 1

1

/

2

minutes.

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where pets or traffic may trigger the control.

• Nearby large, light-colored objects reflecting light

may trigger the shut-off feature. Do not point other
lights at the sensor.

60 ft.

(18.3 m)

The control is most sensitive to motion across it.

Least Sensitive

Most Sensitive

Motion

Sensor

Motion

Clamp
Screw

Ball
Joint

Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor to aim.

Walk through the coverage
area noting where you are
when the lights turn on.
Move the sensor head up,
down, or sideways to
change the coverage area.

Set SENSITIVITY as needed.
Too much sensitivity may in-
crease false triggering.

Secure the sensor head
into position by tighten-
ing the clamp screw.
Do
not overtighten the screw.

Set the amount of TIME the
lights stay on after motion is
detected. It is selectable from
1, 5, or 10 minutes.

Aim Sensor Down

for Short Coverage

Aim Sensor

Higher for Long

Coverage

Bottom of Sensor

ON-TIME

10 5 1 TEST

MIN MAX

SENS

8 ft.

(2.4 m)

Turn the SENSITIVITY (SENS) control to the mid
position and the ON-TIME control to the TEST
position.

Advertising