Extended thin profile unit cooler – Heatcraft Refrigeration Products 25005601 User Manual

Page 10

Advertising
background image

10

FOR FOOD

SERVICE

INSTALLATIONS

. . . seal any joint

between unit cooler

and cooler liner

with a sealant

listed by the

National Sanitation

Foundation,

Standard 51

NOMENCLATURE

LT A 053 A A

Vintage


A = Air Defrost

A = 115-1-60

L = Electric Defrost

B = 208/230-1-60

Size

Extended Thin Profile Unit Cooler

Dimensional Diagram

Extended

Thin Profile

Unit Cooler

Connections- Electric Defrost

Nozzle Selection- Electric Defrost

Air

Electric Number Dimensions (Inches / mm)

Defrost Defrost

of

A

B

C

D

LTA

LTL

Fans Inches

mm

Inches

mm

Inches

mm

Inches

mm

053

046

2

49 3/8

1254

40 7/8

1038

---

---

---

---

079

068

3

69 1/8

1756

60 5/8

1540

---

---

---

---

102

093

4

88 7/8

2257

80 3/8

2042

40 7/8

1038

---

---

134

115

5

108 5/8 2759 100 1/8 2543

40 7/8

1038

---

---

172

133

6

128 3/8 3261 119 7/8 3045

40 7/8

1038

39 1/2

1003

Number

Connections (Inches)

Net

Model

of

Coil

External

Weight

Size

Fans

Inlet

Suction Equalizer Drain

(Lbs.)

LTA 053

2

1/2 OD 5/8 ID

1/4

3/4 MPT

48

LTA 079

3

1/2 OD 5/8 ID

1/4

3/4 MPT

69

LTA 102

4

1/2 OD 7/8 ID

1/4

3/4 MPT

85

LTA 134

5

1/2 OD 7/8 ID

1/4

3/4 MPT

108

LTA 172

6

1/2 OD 1 1/8 ID

1/4

3/4 MPT

124

Number

Connections (Inches)

Net

Model

of

Coil

External

Weight

Size

Fans

Inlet

Suction Equalizer Drain

(Lbs.)

LTL 046

2

1/2 OD 5/8 ID

1/4

3/4 MPT

48

LTL 068

3

1/2 OD 5/8 ID

1/4

3/4 MPT

69

LTL 093

4

1/2 OD 7/8 ID

1/4

3/4 MPT

85

LTL 115

5

1/2 OD 7/8 ID

1/4

3/4 MPT

108

LTL 133

6

1/2 OD 1 1/8 ID

1/4

3/4 MPT

124

Number Air Distributor Tube Number

of

Defrost OD Length

of

Fans

LTA (Inches) (Inches) Circuits R404A R22

2

053

3/16 21 1/2

2

L-1/2 L-1/3

3

079

3/16 21 1/2

2

L-1/2 L-1/3

4

102

3/16 21 1/2

4

L-3/4 L-1/2

5

134

3/16 21 1/2

4

L-1

L-3/4

6

172

3/16 21 1/2

5

L-1 1/2 L-1

Number Electric Distributor Tube Number Low Temp.

Medium Temp.

of

Defrost OD Length

of

-30ºF to 0ºF SST +10ºF to +25ºF SST

Fans

LTL (Inches) (Inches) Circuits R404A R22 R404A R22

2

046

3/16 21 1/2

3

L-3/4 L-1/2

L-1/2

L-1/3

3

068

3/16 21 1/2

3

L-3/4 L-1/2

L-3/4

L-1/2

4

093

3/16 21 1/2

5

L-1

L-3/4

L-1

L-3/4

5

115

3/16 21 1/2

5

L-1 1/2 L-1

L-1

L-3/4

6

133

3/16 21 1/2

5

L-1 1/2 L-1

L-1 1/2

L-1

Dimensional Data

Connections- Air Defrost

Nozzle Selection- Air Defrost

Advertising