Wall mount back bar unit cooler – Heatcraft Refrigeration Products 25005601 User Manual
Page 15
15
Wall Mount Back Bar Unit Cooler
Dimensional Diagram
Mounting
The Wall Mount Back Bar Unit Cooler is a low height unit designed for undercounter applications. Air is drawn in at the
bottom of the unit and discharged out the front. Two mounting angles are included with the unit and should be installed
to space the unit 3/4” off the wall. Air deflector(s) are included and can be mounted over the top half of the fan guard
to direct the air up. The deflector may be left off if total horizontal air movement is desired. If used, the deflector can be
field formed to direct the air where needed. Locating holes and screws are provided.
Dimensional Data
Approx.
Model
BTUH
Motor Data
Dimensions (In.)
Ship Wt.
BB
10°F TD
CFM
Qty.
HP
W
A
B
C
D
E
F
(Lbs.)
L10
1,000
90
1
1/150
19
3
/
4
19
1
/
8
18
17
1
/
2
7
1
/
16
-
16
5
/
8
17
M11
1,100
90
1
1/150
19
3
/
4
19
1
/
8
18
17
1
/
2
7
1
/
16
-
16
5
/
8
16
L15
1,500
180
2
1/150
26
1
/
4
25
5
/
8
24
1
/
2
24
4
13
/
16
8
5
/
8
23
1
/
8
20
M16
1,600
180
2
1/150
26
1
/
4
25
5
/
8
24
1
/
2
24
4
13
/
16
8
5
/
8
23
1
/
8
19
Low
-10°F Sat. Suction Temp.
-15°F Sat. Suction Temp.
Temp BTUH @ R-404A
BTUH @ R-404A
Model 10°F TD
Alco
Sporlan
15°F TD
Alco
Sporlan
BBL10
1000
HFS-1/8SZ
EFS-1/8Z
1500
HFS-1/8SZ
EFS-1/8Z
BBL15
1500
2250
HFS-1/4SZ
EFS-1/6Z
Med
25°F Sat. Suction Temp.
20°F Sat. Suction Temp.
Temp BTUH @ R-22
BTUH @ R-22
Model 10°F TD
Alco
Sporlan
15°F TD
Alco
Sporlan
BBM11
1100
HFS-1/4HC
EFV-1/5C
1870
HFS-1/4HC
EFV-1/5C
BBM16
1600
2720
Expansion Valve Recommendations
Replacement Parts
Description
All Sizes Part No.
115V Motor
25300701
208/230V Motor
25300801
Fan Blade
5101B
Fan Guard
5054D
Motor Mount
91179001
NOMENCLATURE
BB L S 10 A G
A = 115-1-60
B = 208/230-1-60
Revision
Back Bar Unit
Cooler
L = Low Temp Unit
M = Med. Temp Unit
Size
Blank = Std. Unit
S = Slave Unit
M = Master Unit
FOR FOOD
SERVICE
INSTALLATIONS
. . . seal any joint
between unit cooler
and cooler liner
with a sealant
listed by the
National Sanitation
Foundation,
Standard 51
NOTE: All units have 3/8 O.D. suction, 1/2 O.D. sweat inlet connection and 1/2 O.D. drain.