Wall mount back bar unit cooler – Heatcraft Refrigeration Products 25005601 User Manual

Page 15

Advertising
background image

15

Wall Mount Back Bar Unit Cooler

Dimensional Diagram

Mounting

The Wall Mount Back Bar Unit Cooler is a low height unit designed for undercounter applications. Air is drawn in at the

bottom of the unit and discharged out the front. Two mounting angles are included with the unit and should be installed

to space the unit 3/4” off the wall. Air deflector(s) are included and can be mounted over the top half of the fan guard

to direct the air up. The deflector may be left off if total horizontal air movement is desired. If used, the deflector can be

field formed to direct the air where needed. Locating holes and screws are provided.

Dimensional Data

Approx.

Model

BTUH

Motor Data

Dimensions (In.)

Ship Wt.

BB

10°F TD

CFM

Qty.

HP

W

A

B

C

D

E

F

(Lbs.)

L10

1,000

90

1

1/150

19

3

/

4

19

1

/

8

18

17

1

/

2

7

1

/

16

-

16

5

/

8

17

M11

1,100

90

1

1/150

19

3

/

4

19

1

/

8

18

17

1

/

2

7

1

/

16

-

16

5

/

8

16

L15

1,500

180

2

1/150

26

1

/

4

25

5

/

8

24

1

/

2

24

4

13

/

16

8

5

/

8

23

1

/

8

20

M16

1,600

180

2

1/150

26

1

/

4

25

5

/

8

24

1

/

2

24

4

13

/

16

8

5

/

8

23

1

/

8

19

Low

-10°F Sat. Suction Temp.

-15°F Sat. Suction Temp.

Temp BTUH @ R-404A

BTUH @ R-404A

Model 10°F TD

Alco

Sporlan

15°F TD

Alco

Sporlan

BBL10

1000

HFS-1/8SZ

EFS-1/8Z

1500

HFS-1/8SZ

EFS-1/8Z

BBL15

1500

2250

HFS-1/4SZ

EFS-1/6Z

Med

25°F Sat. Suction Temp.

20°F Sat. Suction Temp.

Temp BTUH @ R-22

BTUH @ R-22

Model 10°F TD

Alco

Sporlan

15°F TD

Alco

Sporlan

BBM11

1100

HFS-1/4HC

EFV-1/5C

1870

HFS-1/4HC

EFV-1/5C

BBM16

1600

2720

Expansion Valve Recommendations

Replacement Parts

Description

All Sizes Part No.

115V Motor

25300701

208/230V Motor

25300801

Fan Blade

5101B

Fan Guard

5054D

Motor Mount

91179001

NOMENCLATURE

BB L S 10 A G

A = 115-1-60

B = 208/230-1-60

Revision

Back Bar Unit

Cooler

L = Low Temp Unit

M = Med. Temp Unit

Size

Blank = Std. Unit

S = Slave Unit

M = Master Unit

FOR FOOD

SERVICE

INSTALLATIONS

. . . seal any joint

between unit cooler

and cooler liner

with a sealant

listed by the

National Sanitation

Foundation,

Standard 51

NOTE: All units have 3/8 O.D. suction, 1/2 O.D. sweat inlet connection and 1/2 O.D. drain.

Advertising