Figure 3-2 Sample of Alarm Input (Normal Close Type)

Alarm Output Port

 Three ways to relay alarm output (NO contact). External power supply

is needed for external alarm device.

 To avoid overloading, please read the following relay parameters sheet

carefully.

 6 ways relay alarm output (NO contact). Provide external power to

external alarm device.

 For controllable +12V, it can be used to provide power to devices such

as reset smoke sensor.

Table 3-1 Relay Specification:

Model JRC-27F

Material of the touch

Silver

Rated switch capacity

30VDC 2A, 125VAC 1A

Maximum switch power

125VA 160W

Maximum switch voltage

250VAC, 220VDC

Rating (Resistance
Load)

Maximum switch currency

1A

Between touches with same
polarity

1000VAC 1minute

Between touches with
different polarity

1000VAC 1minute

Insulation

Between touch and winding 1000VAC 1minute