Troubleshooting, Pressure washer stops suddenly, Water leaking from within the housing – Harbor Freight Tools 99741 User Manual

Page 20

Advertising
background image

For technical questions, please call 1-800-444-3353.

SKU 99741

PAGE 20

If the steps above do not solve the problem or if the repairs involved are

too complex, contact a qualified technician.

Shut off the Pressure Washer, release all pressure in a safe

manner, and disconnect it from power and water before adjusting,

cleaning, or repairing the unit.

trOubleShOOtIng

the following points should

be applied to help reduce the

frequency of rest periods:

eliminate any extension cord used.

1.

use proper operating techniques.

2.

review the Operating tips section,

starting on page 14.
Verify that this unit is being supplied

3.

with the correct voltage, see page 11,

#2. connect the plug to the outlet

nearest the circuit breaker panel and

remove any other loads that may be

on the circuit.

Pressure Washer Stops Suddenly

dry self thoroughly

and check the

circuit breaker on

your household

panel.

make sure unit is

totally dry, then

press reset button.

If gFcI continues

to trip, contact

a certified

electrician.

check for electrical shorts.

If none are found, reset

breaker.

If breaker continues to

trip, try another circuit

or contact a certified

electrician.

breaker

nOt trIPPed

breaker trIPPed

the thermal safety Switch may be

tripped. Switch the unit off. allow the

unit to rest for 20-30 minutes and retry.

unIt OPerateS

nOrmallY aFter

reStIng

unIt dOeS nOt

reStart

check the indicator on the gFcI

power plug (explained under Controls

and Features, #1 on page 10).

contact

qualified

technician.

Water leaking from within the housing

Seals may be worn or damaged.

leaking water creates a shock hazard.

ImmedIatelY discontinue use. have the unit repaired

by a qualified technician before further use.

IndIcatOr dOeS

nOt aPPear

IndIcatOr

aPPearS

Advertising