Power

ProLiant DL160 G6 Fully Configured

115V/60Hz

220V/50Hz

Fully Loaded System Input Wattage (W)

448

445

Fully Loaded System Input Current (A rms)

3.833

2.046

Fully Loaded System Thermal (BTU- Hr)

1529

1518

Fully Loaded System VA (Volt-Amp)

449

454

System Inrush Current with all power supplies loaded (A)

10.1

10.96

Power cord requirements

Nema 5-15P to IEC320-C13

IEC320-C13 to IEC320-C14

NOTE: Power shown is for a fully configured system consisting of (2) CPU, (8) double-sided DIMMs, (2) HDDs, (1) CD-ROM, and (2)
PCI cards.

Power Cord

AF556A

Server Power Cords

One 6' Highline (IEC-IEC) power cord ships standard

NOTE: HP ProLiant DL servers no longer ship standard with NEMA power cords (163719-002) that
allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected
to PDU's in data center racks so they now ship standard with only a PDU power cord (416151-B21). If a
user wishes to power a ProLiant DL server using a 110V receptacle (NEMA-15), the NEMA power cord
(227099-001) must be ordered separately.

If customers require a local power cord, they can check the power cord matrix for the appropriate cord.
Please see the following power cord matrix:

http://www.hp.com/go/powercordmatrix

.