Troubleshooting

Your XPan II is a fully professional camera and should provide many years of service particularly if the advice is followed
under 'Equipment Care, Service and Guarantee'. If a problem arises, however, check back in this manual to the relevant
section first taking particular note of the specific warnings. Then check the table below to see if you can solve it. Refer to a
Hasselblad Authorised Service Centre if the problem persists.

Problem

Possible cause / solution

Camera does not react when
the release button is pressed.

• Mode selector in 'OFF7 position.

• Batteries omitted or exhausted.

You cannot attach the lens.

• Ensure lens indexes are aligned.

You cannot remove the lens.

• Depress lens release button while turning lens.

New film has not wound on to
first frame.

• Film tip incorrectly positioned before closing camera back.

• ISO setting to DX position with a non-DX coded film cassette.

Whole film under/ overexposed.

• Manual film speed (ISO) set incorrectly.

• Exposure compensation not set at zero.

Some frames unexposed.

• Lens cap not removed.