Caution, Checkout – Honeywell CT8602C User Manual

Page 5

Advertising
background image

5

69-0446—2

FAN

Move the system switch to OFF, and the fan switch to

ON. The fan should run continuously. When the fan switch
is in the AUTO position, the fan cycles with the heating or
cooling system.

INSTALLER SELF-TEST (Optional)

Perform the following test as a check of all thermostat

functions. If thermostat does not respond as indicated,
replace thermostat.

1. Press AHEAD and BACK keys at the same time.

while holding down keys, all segments of the display should
be on (see Fig. 13).

Fig. 13—All segments on display.

Checkout

HEATING

Move the system switch to HEAT and the fan switch to

AUTO. Press WARMER key until the setting is about 10

°

F

(6

°

C) above room temperature. Heating should start and

the fan should run after a short delay. Press COOLER key
until the setting is about 10

°

F (6

°

C) below room tempera-

ture. The heating equipment should shut off.

COOLING

CAUTION

Do not operate cooling if outdoor temperature is
below 50

°

F (10

°

C). Refer to manufacturer’s rec-

ommendations.

NOTE: When cooling setting is changed, thermostat will

wait up to five minutes before turning on the air condi-
tioner. This delay protects the compressor.

Move the system switch to COOL and the fan switch to

AUTO. Press COOLER key until the setting is about 10

°

F

(6

°

C) below room temperature. The cooling equipment and

fan should start. Press WARMER key until the setting is
about 10

°

F (6

°

C) above room temperature. The cooling

equipment and fan should stop.

2. Set system switch to OFF. Press AHEAD and BACK

and PRESENT SETTING keys at the same time to enter
self-test.

3. Press each key as listed on next page, and look for

response listed as key is held down and released.

SUN MON TUE WED THU FRI SAT COOL ON HEAT ON

WAKE LEAVE RETURN SLEEP TEMPORARY

M8856

AM

PM

REPL

BAT

SET
PT