Caution, Installer setup, Temperature settings – Honeywell Chronotherm IV T8602C User Manual

Page 5

Advertising
background image

69-1567

5

T8602C CHRONOTHERM

®

IV DELUXE PROGRAMMABLE THERMOSTATS

Temperature Settings

Refer to Table 2 for the default program. If the daytime
energy savings period is not used, press the period key
(Leave or Return) until the time is blank. The fan setting
feature is available on select thermostat models. See
Owners Guide, form number 69-0940, for complete
instructions on changing the program.

Table 2. Default Program Settings.

Fig. 9. Display of Installer Setup number and setting.

CAUTION

Electric heat systems must be configured to 1 in
Installer Setup number 2 to prevent equipment
damage caused by the system running without
the fan.

IMPORTANT

Only configurable numbers are shown on the
device. Example: If thermostat does not have a
system key, Installer Setup Number 12 will not
be displayed. Review Table 3 factory-settings
and mark any desired changes in the Actual
Setting column. When Installer Setup is
complete, review the settings to confirm that
they match the system.

INSTALLER SETUP

NOTE: For most applications, the thermostat factory-

settings will not need to be changed. Review
the factory settings in Table 2 and if no
changes are necessary, go to the Installer Self-
Test section.

The Installer Setup is used to customize the thermostat
to specific systems. Some of the options include
temperature display, system changeover and outdoor
temperature display. Installer Setup numbers are listed
in Table 3. The table includes all the configuration
options and the factory-settings for the T8602.

A combination of key presses are required to use the
Installer Setup feature.

To enter the installer setup, press and hold the
information

i

key with the increase

and

decrease

keys until the first number is displayed.

All display segments appear for approximately
three seconds before the number is displayed. See
Fig. 8 and 9.

To advance to the next Installer Setup, press the
Time

key.

To change a setting, use the increase

or

decrease

key.

To scroll the Installer Setup numbers backwards,
press the Time

key.

To exit the Installer Setup, press Run Program.

Fig. 8. Display of all the segments of the LCD.

M14618

INSTALLER SETUP
NUMBER DISPLAY
(COLUMN 2 OF TABLE 3)

FACTORY SETTING OR OTHER
CHOICE DISPLAY (COLUMN 3
OR 5 OF TABLE 3)

Period

Time

Heat

Setpoint

Cool

Setpoint

Fan

Setting

Wake

6:45 AM

20°C

25°C

Auto

Leave

8:45 AM

4.5°C

37°C

Auto

Return

5:00 PM

20°C

25°C

Auto

Sleep

10:00 PM

4.5°C

37°C

Auto

M14559

Aux Ht

Set Day/Time

Set Program

Mon

Wake Leave Return

Sleep

Outdoor

Room

Filter

Wait

System

Fan

Em Heat

On

Auto

Off

Cool

Auto

AM

PM

Hold for

Heat

Cool

Repl Batt

Recovery

DST

Tue Wed Thu Fri Sat Sun

Days

Temporary Setting

Em Ht