Position the Indoor Unit Mounting Plate (4) against the wall, aligning the four

small rectangular openings in the Mounting Plate with the four pre-drilled holes in

the wall. Screw four Screws (5) with four Washers (5) into the plastic Wall An-

chors (5) to secure the Mounting Plate to the wall.

NOtE: Use a leveling device

to ensure the Mounting Plate is straight and level before tightening the Screws.

(See Figure c.)

OutDOOR uNIt MOuNtINg PlAtE

(7)

ScREW (8)

ScREW (8)

ScREW

(5)

WASHER

(5)

WAll ANcHOR

(5)

5 Ft.

FIguRE D

Loosen the two Screws (8) and remove the Outdoor Unit Mounting Plate (7) from

the Outdoor Unit (11).

(See Figure D.)

Select a location for the Outdoor Unit Mounting Plate (7) to be mounted to the

exterior wall, making sure to avoid direct sunshine and rain.
Position the Outdoor Unit Mounting Plate (7) against the wall at a height of five

feet from the floor/ground surface.

NOtE: Make sure to use a leveling device to

ensure the Mounting Plate is straight and level against the wall.

(See Figure D.)

Using the two small openings in the Outdoor Unit Mounting Plate (7) as a tem-

plate, mark the spots where two 1/8” diameter holes will be drilled in the wall.

(See Figure D.)
Temporarily remove the Outdoor Unit Mounting Plate (7) from the wall. Then, drill

the two pre-marked 1/8” diameter holes in the wall.

(See Figure D.)

Insert one plastic Wall Anchor (5) into each of the two pre-drilled holes in the wall.

(See Figure D.)
Position the Outdoor Unit Mounting Plate (7) in a shaded spot against the wall,

aligning the two openings in the Mounting Plate with the two pre-drilled holes in

the wall. Screw two Screws (5) with two Washers (5) into the plastic Wall An-

chors (5) to secure the Mounting Plate to the wall.

NOtE: Use a leveling device

6.