Amana – Honeywell CT70 User Manual

Page 11

Advertising
background image

11

AMANA

!

Jumper these two terminals if both are present

#

This terminal must be connected to transformer common.

$

Remove this factory-installed jumper for independent stage 1

heat and cool connection.

W1

Wiring

terminal

function

Existing

thermostat

wiring

New

thermostat

wiring

COMMON

POWER

COMPRESSOR

1

ST

STG.

HEAT

AUX. HEAT

FAN

C/O VALVE

HEAT

C/O VALVE

COOL

EM. HEAT

SYSTEM

MONITOR

W1

W2

W2

G

G

O

O

L

3

C

X

2

X1

or

RH

R

RC

or

R

or

1

Y1

Y1

Y

or

B

B

or

E

E

W

Advertising