Honeywell CT70 User Manual

Page 9

Advertising
background image

9

FAN:

When this terminal is activated, the fan is

on. With the fan switch in the auto

position, the fan cycles on and off with the

heat pump. With the fan switch in the ON

position, the fan is

on continuously.

MULTIPLE AUX.

HEAT LOADS:

This terminal is activated when additional

auxiliary heat loads are required. Because

the CT70 only has provisions for one

auxiliary heat load, these loads must be

connected to the AUXILIARY HEAT

terminal.

OUTDOOR

SENSOR:

This terminal is not connected to the

CT70. On your original thermostat, this

terminal was activated by an outdoor

sensor that controlled the auxiliary heat

source.

OUTDOOR STAT:

Outdoor Thermostat. This terminal is

activated when the system switch is in the

EM. HT. position. The outdoor thermostat

controls the amount of auxiliary heat that

is activated.

POWER:

This terminal connects to the power side

of the 24-volt transformer.

COMMON:

This terminal connects to the common

side of the 24-volt transformer.

SYSTEM MONITOR:

Some heat pumps have the ability to

indicate when the heat pump is

malfunctioning. When this occurs, this

terminal is activated and the EM. HT. LED

is activated.