SYMBOLOGY

Double Insulated

Canadian Standards
Association

Underwriters
Laboratories, Inc.

Volts Alternating Current

Amperes

No Load Revolutions
per Minute (RPM)

no

xxxx/min.

A

V ~

RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*

(120 VOLT)

NAMEPLATE
AMPERES
(At Full Load)

EXTENSION CORD LENGTH

25 FEET

50 FEET 75 FEET 100 FEET 150 FEET

0 - 2.0

18

18

16

16

16

2.1 - 3.4

18

18

16

14

14

3.5 - 5.0

18

18

16

14

12

5.1 - 7.0

18

16

14

12

12

7.1 - 12.0

18

14

12

10

-

12.1 - 16.0

14

12

10

-

-

16.1 - 20.0

12

10

-

-

-

FIGURE C

*Based on limiting the line voltage drop
to five volts at 150% of the rated amperes.

PAGE 8

6.

If you are using an extension cord outdoors, make sure it is marked with the suffix
“W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.

7.

Make sure your extension cord is properly wired and in good electrical condition.
Always replace a damaged extension cord or have it repaired by a qualified electrician
before using it.

8.

Protect your extension cords from sharp objects, excessive heat, and damp or wet
areas.