B) km-1601swh/3 and km-1601srh/3 "e" control board, E" control board – Hoshizaki KM-1601SAH/3 User Manual

Page 29

Advertising
background image

29

• "ALARM RESET" Button

• "OUTPUT TEST" Button

(used to test relays on control board)

• WHITE K3 Connector

Harvest Control
(thermistor)

• RED K4 Connector

Mechanical Bin Control

(open on units with

thermostatic bin control)

• Label

(control board revision
level indicated on label
on side of relay)

• BLACK K5 Connector

Float Switch

• Part Number

• K1 Ten-Pin Connector

Pins #1 through #10
#1, 9-LED 1 on:
Compressor Relay/
Magnetic Contactor and
Fan Motor-Remote (FMR)
#2-LED 2 on: Hot Gas
Valve (HGV)
#3-LED 2 off: Liquid Line
Valve (LLV

)

#4-LED 3 off: Pump Motor
(PM) in Freeze
#5-LED 3 on: Pump Motor
(PM) in Pump-Out
#6-LED 4: Inlet Water Valve
(WV)
#7, 10 Supply Voltage
#8 Open

• Freeze Timer LED

(yellow)

• S4 Dip Switch

• Harvest Timer LED

(orange)

• Alarm Buzzer

• Power LED (red)

(lights when 10.5VAC
is supplied to K2
connector)

• LED 2 (X2 Relay)

LED 2 ON:
K1 Connector Pin #2
LED 2 OFF:
K1 Connector Pin #3

• LED 3 (X3 Relay)

LED 3 on:
K1 Connector Pin #5
(energized during
harvest pump timer)
LED 3 off:
K1 Connector Pin #4
(energized in freeze)

• LED 4 (X4 Relay)

K1 Connector Pin #6

• LED 1 (X1 Relay)

K1 Connector Pin #1, #9

• K2 Connector

Control Transformer (10.5VAC)

• Relay LEDs (green)

(indicate which
relays and K1
connector pins are
energized)

b) KM-1601SWH/3 and KM-1601SRH/3 "E" Control Board

"E" Control Board

Part Number 2A1410-01 (factory);

2A1410-02 (service)

"E" Control Board

• "C" "ALP" Switch

Switch for "C" control board
and "ALPINE" control board

(service control board only)

Advertising