B) harvest timer (s4 dip switch 1 & 2), C) pump-out timer (s4 dip switch 3 & 4), Caution – Hoshizaki KM-1601SAH/3 User Manual

Page 33

Advertising
background image

33

b) Harvest Timer (S4 dip switch 1 & 2)

The harvest timer starts when the thermistor reads 48°F (9°C) at the evaporator outlet
and the control board reads the thermistor's 3.9 kΩ signal. The harvest timer is factory
set, and generally no adjustment is required. However, a setting longer than the factory
setting may be advised in cases where the flush provided at harvest needs to be
prolonged for extra cleaning. Before changing this setting, contact Hoshizaki Technical
Support at 1-800-233-1940 for recommendations. Keep in mind that setting the harvest
timer to a longer setting decreases 24-hour production.
Note that the pump-out timer (S4 dip switch 3 & 4) acts in place of the harvest timer
during cycles with a pump-out. For details, see "II.C.3.c) Pump-Out Timer (S4 dip switch
3 & 4)."

S4 Dip Switch Setting

Time

(seconds)

No. 1

No. 2

OFF

OFF

60

ON

OFF

90

OFF

ON

120

ON

ON

180

c) Pump-Out Timer (S4 dip switch 3 & 4)

CAUTION

Do not adjust S4 dip switch 3 off and S4 dip switch 4 on for KM-1601SAH/3.
Otherwise, pump motor does not rotate in the pump-out direction.

When a pump-out is called for, the pump motor stops after the preceding freeze cycle.
The pump motor restarts 2 seconds later in the reverse direction, taking water from the
bottom of the water tank and forcing pressure against the pump-out check valve seat
allowing water to go through the pump-out check valve and down the drain. At the same
time, water flows through the small tube to power flush the float switch. The pump motor
drains the water tank for the time determined by the pump-out timer. The pump-out timer
also acts in place of the harvest timer during cycles with a pump-out. The pump-out timer
is factory set, and generally no adjustment is required. The pump-out timer control can
be set to pump-out for 10 or 20 seconds.

S4 Dip Switch Setting Time (seconds)

Inlet

Water

Valve

No. 3

No. 4

T1

T2

OFF

OFF

10

150

closed

ON

OFF

10

180

closed

OFF

ON

10

120

open

ON

ON

20

180

closed

T1: Time to drain the water tank
T2: Harvest timer at pump-out