Warning – Honeywell PERFECT WINDOW ER150C User Manual

Page 7

Advertising
background image

ER150 AND ER200 Perfect Window™ FRESH AIR VENTILATION SYSTEMS

7

69-1563-1

WARNING

Carbon Monoxide Hazard.

Can cause personal injury or equipment damage.

Hood blockage can cause a change of pressure in building which can lead to
possible spillage from combustible appliances.

AIR FILTERS
Air filters should be cleaned twice a year. The standard filters supplied with your
ventilator are removable and washable.

1. Open access door and slide out core. Refer to Core Maintenance section for

cleaning instructions.

2. Remove filter clip.

3. Remove filters from the core and rinse with water or a combination of soap and

water. Do not clean in a dishwasher.

4. After cleaning, place filters (wet or dry) back in their position and reattach the

retaining clip.

CORE

IMPORTANT

Do not wash the core with water or other fluids.

Clean the core twice each year using only a vacuum cleaner.

1. Open the access door and carefully grip the ends of the core and pull evenly out-

ward. The core can be snug, but it will slide out of the cabinet.

NOTE: Do not handle the fins because damage can occur.

CORE GUIDE CHANNEL

FILTER

FILTER CLIP

M11899

Advertising