a

The W8735B prompts for setting the dial-out telephone number type as data or voice; choose voice because data is

reserved for future applications.

5

Pass Code.
This setting provides secure access for the
homeowner’s comfort settings. (Installer: Have the
homeowner enter this setting either at the time of
installation or at their convenience.)

Any combination of four digits.
(Default pass code is 1234.)

6

Zone ID Names (if zoning installed).
When more than one thermostat is installed in a
system, a name can be assigned to each zone
thermostat.

Choose from a list of 26 zone names. (See
Table 4.)

7

Filter Change Setting (enable/disable).
The W8735B can initiate a dial-out alert when the
HVAC equipment filter needs replacing. (If not
desired, set the value to disable.)

Enable or disable. (Enable is the default.)

8

Dial-out Alert Setting (enable/disable).
The W8735B can dial out on an alert condition.
See Table 5. (If not desired, set the value to
disable.)

Enable or disable. (Enable is the default.)

9

Dial-out Telephone Number Settings.
W8735B can store up to three telephone numbers
to dial out

a

:

Telephone number setting one: The
homeowner selects a number where they can
be contacted when away from home (such as
office, second home, or cellular phone
number).

Telephone number setting two: An alternate
contact when the homeowner cannot be
reached (such as relative, friend or neighbor).

Telephone number setting three (HVAC
contractor is providing monitoring service at
homeowner’s request): The HVAC contractor
phone number.

IMPORTANT

If these numbers are not programmed, a
dial-out is not initiated on alert. Tele-
phone setting numbers one and two are
for the homeowner.

Up to three telephone numbers can be
programmed. (Each telephone number
can be any combination of 25 digits.)

10

Power Outage Setting,
The W8735B can monitor if the power is
interrupted (when a 9 Vdc alkaline battery is
installed). When power is interrupted continuously
for longer or equal to the power outage setting, the
W8735B initiates a dial-out alert.

1, 2, 3 or 4 hours. (Factory default is 1
hour.)

11

Software Version Number.
Identifies version of software in Telephone Access
Module.

None