Maintenance

Replacing the UVC Bulb

3

Figure 8

Figure 9

Figure 10

Figure 7

Screws

Uvc Replacement:
Your humidifier is equipped with a UVC bulb to help kill germs and bacteria in the

water. This bulb needs to be replaced once a year. These instructions will assist

you with bulb replacement.

1. Turn the humidifier off and unplug it from the wall outlet.

nOTe: Before replacing the UVC bulb, you must empty the water out of the

humidifer.

2. Remove the water tank from the unit and empty any water in the humidifier

base.

3. Turn the humidifier base over and remove the 2 screws attaching the

compartment to the bottom of the humidifier. Figure 7.

nOTe: Only remove the 2 screws pictured in Figure 7.

4. Grip the tab on the bottom of the UVC compartment and pull straight out.

Figure 7 and Figure 8.

5. Remove the UVC bulb from the UVC cover by turning counterclockwise ,

Figure 9, and lifting it slightly to clear the lip on the UVC compartment. Figure

10

nOTe: When handling the new bulb, do not let it come in direct contact with

your hands. Oils from your skin can cause the bulb to fail directly, or lessen its life

expectancy. Use the bag the bulb came in to screw it into the socket on the UVC

cover.

nOTe: If the UVC cover is not installed properly the humidifer WILL nOT

OPeRATe.

6. Insert the 3 screws that hold the UVC cover, and tighten securely.

7. Reassemble the unit and resume operation.