Listing and code approvals, Warning – Hearth and Home Technologies Fireside Burner/Hearth Kiths MTMHK18NG User Manual

Page 4

Advertising
background image

Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010

4

1

Listing and Code Approvals

A. Appliance Certification

The Gas Log Hearth Kits have been tested and listed in the

U.S. in accordance with

ANSI Z21.84-2003 (Gas Log Set).

They have been listed by OMNI Test Labs for installation and

operation in the United States and Canada as described in

these Installation and Operating Instructions. All components

are UL, OMNI or CSA safety certified.
Check with your local building code agency prior to installing

this appliance to ensure compliance with local codes,

including the need for permits and follow-up inspections. In

the absence of local codes, comply with the

National Fuel

Gas Code, ANSI Z223.1-Latest Edition in the U.S. If any

assistance is required during installation, please contact

your local dealer or call the Technical Services Department

at 1-888-427-3973 or 1-800-927-6841.

B. Table 1

Improper installation, adjustment, alteration, service

or maintenance can cause injury or property damage.

Refer to the owner’s information manual provided with

this appliance. For assistance or additional information

consult a qualified installer, service agency or the gas

supplier.

WARNING

Fire Risk

Exhaust Fumes Risk

• Do NOT use this appliance as a “vent-free

heater.

The flue must be permanently open. Refer

to Table 1.

WARNING

Product

MHK18NG

MHK24NG

STMHK18NG

STMHK24NG

Inlet BTU / KW /HR

Nat.

74,000 / 21.7

84,000 / 24.6

65,000 / 19

75,000 / 22

Max. Inlet Pressure

IN. WC / KPa

Nat.

10.0 / .052

10 / .052

10.0 / .052

10.0 / .052

Min. Inlet Pressure IN.

WC / KPa

Nat.

3.5 / .018

3.5 / .018

3.5 / .018

3.5 / .018

Orifice Size

In. / mm

Nat.

(#26) .147

(#20) .161

(#30) .128

(#28) .141

Minimum Fireplace

Opening Size

In. / cm

Front

28 / 71.1

34 / 86.4

28 / 71.1

34 / 86.4

Rear

16 / 40.6

18 / 45.7

-

-

Depth

14 / 35.6

16 / 40.6

16 / 40.6

16 / 40.6

Height

16 / 40.6

18 / 45.7

18 / 45.7

18 / 45.7

Min. Vent Opening in

Square In. / cm

39 / 251.6

48 / 309.7

39 / 251.6

48 / 309.7

Advertising