A. Gas Supply Connection

Ensure fittings are of the appropriate size and type on the

gas line connection. If the tubing has to be cut to length be

sure to use the proper cutting and flaring tool. Also, be care-

ful not to crimp the tubing while bending. If the tubing be-

comes crimped, do not use for installation.

Fire Risk

Explosion Risk
Verify inlet pressures.

• High pressure may cause overfire

condition.

• Low pressure may cause explosion.
Install regulator upstream of valve if line

pressure is greater than 1/2 psig.

WARNING

3

Appliance Preparation

B. Convert to Left Side Gas Piping

• Remove the brass elbow from the right side.

• Remove the cap from the left side.

Note: Prior to installing the fittings, use Teflon tape or joint

compound on the male threads.

Note: An individual manual shutoff valve (not supplied) is

required when installing this appliance. The manual shutoff

valve must be located in an easily accessible area, no more

than 6 feet from the appliance.

Note: Have the gas supply line installed in accordance

with local building codes, if any. If not, follow

ANSI 223.1.

Installation should be done by a qualified installer approved

and/or licensed as required by the locality. (In the Common-

wealth of Massachusetts installation must be performed by

a licensed plumber or gas fitter.)

Note: A listed (and Commonwealth of Massachusetts

approved) 1/2 in. (13 mm) T-handle manual shut-off valve

and flexible gas connector are connected to the 1/2 in.

(13 mm) control valve inlet.
• If substituting for these components, please consult

local codes for compliance.

WARNING

Gas Leak Risk

• Support control when attaching pipe to

prevent bending gas line.

WARNING

Fire Risk

Explosion Risk

• Gas build-up during line purge may

ignite.

• Purge should be performed by qualified

technician.

• Ensure adequate ventilation.

• Ensure there are no ignition sources such

as sparks or open flames.

Fire Risk

Explosion Risk

Personal Injury Risk
An explosion could occur if a connection is

made directly to an unregulated propane (LP)

tank.

WARNING

Joint compound or Teflon tape must be used on all threaded

male connections to ensure a tight seal.

• Replace the cap on the opposite end of the burner tube.

• Install the brass elbow on the left side of the burner.

Advertising