Troubleshooting – Harbor Freight Tools 67708 User Manual

Page 15

Advertising
background image

Page 15

For technical questions, please call 1-800-444-3353.

SKU 67708

troubleshooting

Problem

Possible causes

likely Solutions

Compressor does

not start or restart

Incorrect power supply.

1.

No power at outlet.

2.

Power cord not plugged in

3.

properly.
Thermal overload switch

4.

tripped.
Building power supply circuit

5.

tripped or blown fuse.

Tank(s) already pressurized.

6.

Cord wire size is too small or

7.

cord is too long to properly

power compressor.
Compressor needs service.

8.

Check that circuit matches compressor requirements.

1.

Reset circuit breaker, or have outlet serviced by a qualified

2.

technician.
Check that cord is plugged in securely.

3.

Turn off Tool. Turn off Compressor and wait for it to cool down.

4.

Press reset button. Resume operation.
Reset circuit or replace fuse. Check for low voltage conditions.

5.

It may be necessary to disconnect other electrical appliances

from the circuit or move the compressor to its own circuit.
No problem. Compressor will start when needed.

6.

Use larger diameter or shorter extension cord or eliminate

7.

extension cord. See Recommended Wire Gauge for Extension

Cords in Safety section.
Have unit inspected by a qualified technician.

8.

Compressor builds

pressure too slowly

Incorrect power supply.

1.

Crankcase overfilled with oil or

2.

oil too thick.
Working environment too cold.

3.

Safety valve needs service.

4.

Loose fittings.

5.

Check that circuit matches compressor requirements.

1.

Drain oil and refill to proper level with recommended oil.

2.

Move unit to a warmer location. Check that recommended oil

3.

is in crankcase.
Listen for air leaking from valve. If leaking replace with

4.

identical valve with same rating.
Reduce air pressure, then check all fittings with a soap solution

5.

for air leaks and tighten as needed. Do not overtighten.

Compressor not

building enough air

pressure

Filters need cleaning/replacing.

1.

Crankcase oil too thick.

2.

Check Valve needs service.

3.

Compressor not large enough

4.

for job.

Loose fittings.

5.

Hose or hose connections not

6.

adequate.
High altitude reducing air

7.

output.

Check inlet and outlet filters. Clean and/or replace as needed.

1.

Drain oil and refill to proper level with recommended oil.

2.

Have technician clean or replace, as needed.

3.

Check if accessory SCFM is met by Compressor. If

4.

Compressor cannot supply enough air flow (SCFM), you need

a larger Compressor.
Reduce air pressure, then check all fittings with a soap solution

5.

for air leaks and tighten as needed. Do not overtighten.
Replace with larger hose and/or hose connections.

6.

You may need a larger compressor if you are situated in a high

7.

altitude location.

High Oil

Consumption

Crankcase oil too thin.

1.

Unit not on level surface.

2.

Crankcase vent clogged.

3.

Drain oil and refill to proper level with recommended oil.

1.

Reposition unit on a level surface.

2.

Clean Crankcase vent.

3.

Follow all safety precautions whenever diagnosing or servicing the

compressor. disconnect power supply before service.

Advertising