Caution, 3 installing the control box – Hearth and Home Technologies WSK-MLT User Manual

Page 3

Advertising
background image

3

1.3 Installing the control box

Figure 4. Standing Pilot Wiring Diagram

For units WITHOUT factory installed Rocker Switch

Standing Pilot Ignition:

Find these parts packed with WSK-MLT:

• Rocker switch

• Rocker switch bracket

• Strips of Velcro

• Black and white wire pigtails - (2)

• Female ends (only used on Standing Pilot

applications) - (2)

Cut male ends off black wires on each pigtail. Strip each
end of wire approximately 1/4 inch. Slide each stripped
wire into a female end and crimp. Slide rocker switch into
bracket until it snaps into place. Attach end of each pigtail
to each side of rocker switch. Find the top (brown) and
bottom (red) wires from the control box and attach to white
wires from rocker switch. Attach one black wire to the TH/TP
side of gas valve and the other to the TH side of the gas
valve. Attach the Velcro to the bottom of the rocker switch
bracket and mount in a convenient location next to gas
valve. (Refer to Figure 4).

For units WITHOUT factory installed rocker switch.

1. Place control box into the base pan area of the fi replace.

Place unit as close to the louvers or decorative front as
possible and to either the left or right side.

2. Connect the red, yellow or white, and green wires to the

appropriate labeled terminals on the control box.

For units WITH factory installed rocker switch.

3. Find the red and brown pigtail wire (labeled “ FOR USE

WITH REMOTE OR WALL SWITCH ONLY”) which are
attached to the fi replace ON/OFF rocker switch.

Standing Pilot Ignition: Connect these wires with the
red and brown wires extending from control box (Fig 2).

Intellifi re (IPI): Connect these wires with the brown
wires extending from the control box (see Figure 3).

• Do NOT install the control box when fi replace is hot.

• Do NOT plug control box in until all connections are

complete.

* May be labeled as “W” or “Y”.

YELLOW

WHITE

BLACK

To

Thermopile

BLACK

BLACK

WHITE

WHITE

VALVE

FAN THERMOSTAT

YELLOW

YELLOW

TOGETHER

CONNECTED

FACTORY

GREEN

RED

AC PLUG

BROWN

BROWN

G

W*

R

BLACK

RED

BLACK

RED

BLACK

BLACK

REAR VIEW

FRONT VIEW

CONNECTION

AUX

GREEN

GROUND PIGTAIL

RED

RED

FLAME HIGH/LOW

USED

NOT

G W* R

CONNECTION

FAN

ORANGE

ORANGE

SOLENOID

FLAME

USED

NOT

SWITCH AND WIRE
ASSEMBLY SUPPLIED
WITH WSK-MLT

CAUTION

Advertising