For units without factory installed rocker switch – Hearth and Home Technologies WSK-MLT User Manual

Page 4

Advertising
background image

4

Intellifi re (IPI):

Find these parts packed with WSK-MLT:

• Rocker switch

• Rocker switch bracket

• Strips of Velcro

• Black and white wire pigtails - (2)

• Female ends (not used on IPI applications) - (2)

Slide rocker switch into bracket until it snaps into place.
Attach one pigtail to one side of rocker switch and the other
pigtail to the other side of the rocker switch. Find the two
brown wires from IPI module and attach them to the two
black wires from the rocker switch. Find the two brown
wires from the control box and attach them to the white
wires from the rocker switch. Attach the Velcro to rocker
switch bracket and place rocker switch next to control box.
(Refer to Figure 5).

Proceed to Step 4.

Figure 5. Intellifi re (IPI) Wiring Diagram

For units WITHOUT factory installed Rocker Switch

* May be labeled as “W” or “Y”.

BROWN

WHITE

BLACK

YELLOW

or

WHITE

BLACK

TOGETHER

CONNECTED

FACTORY

FAN THERMOSTAT

YELLOW

YELLOW

FLAME ON

3V DC

GREEN

RED

BROWN

BLACK

GROUND

BROWN

ADAPTER WIRES

BLACK

RED

RED

BLACK

FLAME HIGH/LOW

SOLENOID

FLAME

MODULE

IPI

ORANGE

G

W*

R

8

7

6

5

4

3

2

1

BATTERIES

ORANGE

CONNECTION

FAN

PLUG

AC

BLACK

BLACK

G W* R

REAR VIEW

FRONT VIEW

CONNECTION

AUX

GREEN

PIGTAIL

GROUND

RED

RED

GREEN

ORANGE

VALVE

IPI

(MALE/FEMALE)

RED

RED

(FEMALE/MALE)

BLACK

RED

SWITCH AND WIRE
ASSEMBLY
SUPPLIED
WITH WSK-MLT

Note: The fan rheostat has now been removed from the
circuit and is inoperable. Use the wall switch to change fan
speeds. The fan temperature sensor is still operable and
will turn the fan on and off when the fi replace heats up and
cools down.

5. Remove the screw and knob from the variable regulator

and discard.

6. Unscrew the nut from the regulator and discard.

7. Remove the bag containing a washer and blue and red

plungers from the side of the fl ame control solenoid.

8. Place washer on fl ame control solenoid (see Figure 6).

4. If equipped with a fan, plug the fan cord into the power

cord labeled “FAN”. Disconnect the two wires from the
fan thermostat switch on the fi replace. Disconnect the
two yellow wires from each other and connect them to
the fan thermostat switch. Use one of the existing wires
on the thermostat to connect to the proper end on the
male terminated yellow wire.