Introduction, Supplied accessories, Important safety information – Harman-Kardon AVR 700 User Manual

Page 3: Place the avr

Advertising
background image

AVR 700/AVR 70/AVR 70C

3

Introduction, Supplied Accessories,

Important Safety Information and Place the AVR

Introduction

Thank you for choosing this Harman Kardon product!

for more than fifty years, the harman kardon mission has been to share a passion for music

and entertainment, using leading-edge technology to achieve premium performance.

Sidney harman and bernard kardon invented the receiver, a single component designed

to simplify home entertainment without compromising performance. over the years,

harman kardon products have become easier to use while offering more features and

sounding better than ever.
the AVr 70, AVr 700 and AVr 70c 5.1-channel digital audio/video receivers (AVrs)

continue this tradition with some of the most advanced audio and video processing

capabilities yet and a wealth of listening and viewing options.
to obtain the maximum enjoyment from your new AVr, please read this manual and refer

back to it as you become more familiar with its features and their operation.
If you have any questions about this product, its installation or its operation, please

contact your harman kardon retailer or custom installer, or visit our web site at www.

harmankardon.com.

Supplied Accessories

the following accessory items are supplied with your AVr. If any of these items are

missing, please contact your harman kardon dealer, or harman kardon customer service

at www.harmankardon.com.

• IR remote control
• AM loop antenna
• FM wire antenna
• Three AAA batteries
• AC power cord

IMPORTANT SAFETY INFORMATION

Verify Line Voltage Before Use

the AVr 700 has been designed for use with 120-volt alternating current (Ac). the

AVr 70 and AVr 70c have been designed for use with 220 – 240-volt Ac. connection

to a line voltage other than that for which your AVr is intended can create a safety

and fire hazard, and may damage the unit. If you have any questions about the voltage

requirements for your specific model or about the line voltage in your area, contact your

selling dealer before plugging the unit into a wall outlet.

Do Not Use Extension Cords

to avoid safety hazards, use only the power cord supplied with your unit. we do not

recommend that extension cords be used with this product. As with all electrical devices,

do not run power cords under rugs or carpets, or place heavy objects on them. damaged

power cords should be replaced immediately by an authorized service center with a cord

meeting factory specifications.

Handle the AC Power Cord Gently

when disconnecting the power cord from an Ac outlet, always pull the plug; never

pull the cord. If you do not intend to use your AVr for any considerable length of time,

disconnect the plug from the Ac outlet.

Do Not Open the Cabinet

there are no user-serviceable components inside this product. opening the cabinet may

present a shock hazard, and any modification to the product will void your warranty. If

water or any metal object such as a paper clip, wire or staple accidentally falls inside

the unit, disconnect it from the Ac power source immediately, and consult an authorized

service center.

CATV or Antenna Grounding (AVR 700)

If an outside antenna or cable system is connected to this product, be certain that it is

grounded so as to provide some protection against voltage surges and static charges.

Section 810 of the united States national electrical code, AnSI/nfpA no. 70-1984,

provides information with respect to proper grounding of the mast and supporting

structure, grounding of the lead-in wire to an antenna discharge unit, size of grounding

conductors, location of antenna discharge unit, connection to grounding electrodes and

requirements of the grounding electrode.
NOTE TO CATV SYSTEM INSTALLER: this reminder is provided to call the cAtV (cable

tV) system installer’s attention to article 820-40 of the nec, which provides guidelines

for proper grounding and, in particular, specifies that the cable ground shall be connected

to the grounding system of the building, as close to the point of cable entry as possible.

Place the AVR

• Place the AVR on a firm and level surface. Be certain that the surface and any

mounting hardware can support the AVr’s weight.

• Provide proper space above and below the AVR for ventilation. Recommended

clearance distances are 30cm above the unit, 10cm behind the unit and 20cm on

each side of the unit.

• If you install the AVR in a cabinet or other enclosed area, provide cooling air within the

cabinet. under some circumstances, a fan may be required.

• Do not obstruct the ventilation slots on the top of the AVR or place objects directly

over them.

• Do not place the AVR directly on a carpeted surface.
• Do not place the AVR in moist or humid locations, in extremely hot or cold locations,

in areas near heaters or heat registers, or in direct sunlight.

Advertising
This manual is related to the following products: