Heat & Glo • CFX-CRESCENT • 705-900 Rev. P • 12/07

22

If the area above the ceiling IS an attic, position and
secure the firestop on top of the previously framed hole.

NOTE: There must be NO insulation or other
combustibles inside the framed firestop opening.

This shows an attic
installation.

1. Keep insulation away

from the vent pipe at
least 1 inch (25 mm).

Figure 16. Attic Firestop

C. Vent Termination

For Horizontal Terminations - The trapezoidal cap
SLK-01TRD is the only cap that is approved to
terminate a horizontal vent run.

To attach and secure the termination to the last
section of horizontal vent:

• Rotate and interlock the ends as described at the

beginning of the Installing Vent Components
section.

• The termination kit should pass through the wall

firestops from the exterior of the building.

• Adjust the termination cap to its final exterior

position on the building (see Figure 17).

CEILING

CEILING FIRESTOP

RAFTER

NAILS (4 REQUIRED)