B. Junction Box Installation

Figure 9.2 Junction box installation

JUNCTION

BOX

SIDEWALL

JUNCTION BOX ACCESS

SCREW

PROVIDED

Optional Accessories

Connecting the electrical junction box is required if using
a blower or remote.

• Plug the cord into a convenient outlet.

• An electrician may install an outlet box inside the fi re-

place. Place the outlet in the lower, back corner of the
fi replace.

• Must use cord supplied.

• Avoid sharp corners.

CAUTION

Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.

Shock hazard.

• Replace damaged wire with type 105º C rated

wire.

• Wire must have high temperature insulation.

WARNING

Advertising