haier MAGNUM 232738 User Manual

Page 12

Advertising
background image

Advanced Troubleshooting

12

309477F

Basic electrical problems

Motor overheated

Allow motor to cool for 30 minutes. Retry.

Electrical outlet is damaged

Reset building circuit breaker or replace building
fuse. Try another outlet.
Check electric supply with volt meter. Meter must
read 200-260V AC. If voltage is too high, do not
plug sprayer in until outlet is corrected.

Control board leads are
improperly fastened or
improperly mated

Replace any loose terminals. Make sure all leads
and harnesses are firmly connected.
Check pressure control harness connection on
front side of drive housing.
Clean control board terminals. Securely reconnect
leads.

Motor brushes are worn.

Check length of BOTH brushes (brushes do not
wear evenly on both sides of the motor). Brush
length must be 6.4mm (0.25 in). If brushes are
worn replace motor using Motor Kit, page 18.

Motor armature commutator
damaged

Check for burn spots, gouges and extreme
roughness. Have motor shop resurface
commutator if possible, or replace motor using
Motor Kit, page 18.

Motor armature shorting

Check for shorts using armature tester (growler)
or perform spin test, Motor Diagnostic, page 19.
If shorts are evident, replace motor using Motor
Kit
, page 18.

Control board damaged.
CAUTION: Do not perform
control board diagnostics until
you have determined the
armature is good. A bad
armature can burn out a good
control board.

See Control Board Diagnostics, page 19.
Replace control board if damaged using Control
Board Kit
, page 18.

Sprayer Wiring Problems
NOTE: Remove enclosure
mounting screws and pull
enclosure away from drive
housing. Take care not to pull
on leads from electrical cord
and power switch.

Sprayer electrical cord
damaged

1. Unplug sprayer electrical cord.
2. Disconnect black electrical cord wire at

power switch

3. Unplug in-line connection white cord wire.
4. Plug in electrical cord
5. Test voltage between black and white

wires. Meter must read 200-260 V AC.

6. Replace electrical cord if no voltage.

Sprayer power switch damaged

1. Unplug sprayer electrical cord.
2. Disconnect black control board wire at

power switch.

3. Unplug in-line connection white cord wire.
4. Plug in electrical cord.
5. Turn power switch ON.
6. Test voltage between open terminal of

power switch and white electrical cord wire.
Meter must read 200-260 V AC.

7. Replace power switch if no voltage.

Specific Problem

Cause

Solution

Advertising