General problem: circuit breaker is tripping – haier MAGNUM 232738 User Manual

Page 13

Advertising
background image

Advanced Troubleshooting

309477F

13

Sprayer Wiring Problems
(cont.)

Motor thermal overload cutoff
switch damaged.
Thermal Overload, page 7.

1. Unplug sprayer electrical cord.
2. Remove motor harness from control card
3. Check for continuity between yellow leads

or motor harness.

4. If thermal relief switch is open (no continu-

ity) allow motor to cool.

5. If switch remains open after motor cools,

replace motor using Motor Kit, page 18.

6. If thermal relief switch closes after motor

cools, find correct cause of overheating.

Terminals are damaged or
loose

Replace any damaged terminals. Make sure all
terminal connections are tight.

Specific Problem

Cause

Solution

General Problem: Circuit Breaker is Tripping

Specific Problem

Cause

Solution

Building circuit breaker opens
as soon as sprayer is turned on

Sprayer electrical wiring is
pinched or insulation is
damaged.

Repair or replace any damaged wiring or
terminals. Securely reconnect wires.

Wires between pressure
control switch and control
board are pinched

Motor armature is shorting

Check for shorts using armature tester (growler)
or perform spin test, Motor Diagnostics, page
19. If shorts are evident, replace motor using
Motor Kit, page 18.

Control board is damaged.
CAUTION: Do not perform
control board diagnostics until
you have determined the
armature is good. A bad motor
armature can burn out a good
motor control board.

See Control Board Diagnostics, page 19.
Replace control board if damaged using Control
Board Kit
, page 18.