Caution, Wiring, T8511g deluxe heat pump zone thermostat – Honeywell DELUXEHEATPUMP T8511G User Manual

Page 2

Advertising
background image

69-1052—1

2

T8511G DELUXE HEAT PUMP ZONE THERMOSTAT

Fig. 1. Typical location of thermostat.

Fig. 2. Mounting the wallplate.

Wiring

All wiring must comply with local electrical codes and
ordinances. Refer to Fig. 3 and 4 for typical hookups. A
letter code is located near each terminal for identification.

CAUTION

Disconnect power before wiring to prevent
electrical shock or equipment damage.

1. Loosen the terminal screws on the wallplate and

connect the system wires. See Fig. 5.

IMPORTANT

Use 18 gauge, color-coded thermostat cable for
proper wiring.

2. Securely tighten each terminal screw.
3. Push excess wire back into the hole.
4. Plug the hole with nonflammable insulation to

prevent drafts from affecting the thermostat.

5 FEET

[1.5 METERS]

YES

NO

NO

NO

M10106

WIRES
THROUGH WALL

WALL

MOUNTING
HOLES

MOUNTING
SCREWS

M6530

WALL
ANCHORS
(2)