HP 30 HP30 User Manual

Page 108

Advertising
background image

Chapter 6 - Parameter Description [FU2]

6-16

FU2-07: Dwell Frequency
FU2-08: Dwell Time











This function is used to output torque in an intended
direction. It is useful in hoisting applications to get enough
torque before a releasing mechanical brake. If the dwell
time is set at ‘0’, this function is not available. In dwell
operation, the inverter outputs AC voltage not a DC
voltage.

Note: DC Injection Braking does not output torque to an

intended direction. It is just to hold the motor.





















[Dwell Operation]

FU2-10 ~ FU2-16: Frequency Jump
























To prevent undesirable resonance and vibration on the
structure of the machine, this function locks out the
potential resonance frequency from occurring. Three
different jump frequency ranges may be set. This
avoidance of frequencies does not occur during
accelerating or decelerating. It only occurs during
continuous operation.










[Frequency Jump]

FU2

► Dwell freq

07 5.00 Hz

5.00

07

Factory Default:

5.00 Hz

5.00

FU2

► Dwell time

08 0.0 sec

0.0

08

Factory Default:

0.0 sec

0.0

FX-CM

ON

Output Frequency

Time

Time

Run Command

FU1-07

t1

t1: FU2-08 [Dwell Time]

Output Current

Time

Mechanical

Brake

Release

Time

FU2

► Jump freq

10 --- No ---

0

10

Factory Default:

No

0

Output Frequency

Freq. Max

Reference
Frequency

10Hz

20Hz 30Hz

FU2-12

FU2-11

FU2-14
FU2-13

FU2-16
FU2-15

FU2

► jump lo 1

11 10.00 Hz

10.00

11

Factory Default:

10.00 Hz

10.00

FU2

► jump Hi 1

12 15.00 Hz

15.00

12

Factory Default:

15.00 Hz

15.00

FU2

► jump lo 3

15 30.00 Hz

30.00

15

Factory Default:

30.00 Hz

30.00

FU2

► jump Hi 3

16 35.00 Hz

35.00

16

Factory Default:

35.00 Hz

35.00

Advertising