Set temperature setpoint, Setting °f/°c indication and heat cycle rate – Honeywell HEAT PUMP THERMOSTAT T8411R User Manual

Page 5

Advertising
background image

T8411R ELECTRONIC HEAT PUMP THERMOSTAT

5

69-1481-1

Set Temperature Setpoint

NOTE: Temperature setpoint range is 40° to 99°F (4° to

39°C).

The temperature setpoint and the room temperature are

shown separately on the digital display. The ▼ indicator
points to Set when the temperature setpoint is displayed

and to Room when the room temperature is displayed
.

To set temperature setpoint:

1. Select Heat or Cool by sliding the SYSTEM switch

in the lower right corner of the thermostat to the

desired mode. See Fig. 7.

2. To display the temperature setpoint on the digital

display, press either the ▲ or ▼ key once. The
temperature setpoint is displayed for approxi-

mately five seconds as the indicator points to Set
and flashes.

3. To increase the temperature setpoint press the ▲

key. Each press changes the setpoint one degree;

press and hold to change the setpoint several
degrees.

4. To decrease the temperature setpoint press the ▼

key. Each press changes the setpoint one degree;

press and hold to change the setpoint several
degrees.

Setting °F/°C Indication and Heat Cycle Rate

NOTE: To save changes to the °F/°C indication and the

heat cycle rate, all seven steps must be com-

pleted.

In installer setup mode, steps 2 through 5, each
press of the ▲ key momentarily displays 01 and

each press of the ▼ key momentarily displays
02. When the keys are released, these two-digit

codes are no longer displayed.

To set the °F/°C indication and heat cycle rate:

1. If the temperature is displayed in °F, set the tem-

perature setpoint to 52°F. If the room temperature
is displayed in °C, set the temperature setpoint to

11°C.

2. Press the ▲▼ keys simultaneously for more than

one second to light all segments on display and to

enter installer setup mode. When the keys are
released, a two-digit software revision code is dis-

played.

OPTIONAL SYSTEM CHECKOUT
When the heat or cool outputs are turned on, the five-

minute off-timer safety feature is bypassed.

When in steps 2 and 3 only, the key can be used to
turn heat or cool outputs on and off. Change the

SYSTEM switch setting to test heat or cool outputs. No
action takes place If the system switch is in the Off

position.

The following examples of system settings show a two
digit software code on the display. The code shown is

only an example; codes may vary.

System setting at Heat:

To turn heat on, press the ▼ key.

To turn auxiliary heat on, press the ▼ key.

To turn auxiliary heat off, press the ▼ key a third time.

To turn heat off, press the ▼ key a fourth time.

System setting at Cool:

To turn cool on, press the ▼ key.

To turn cool off, press the ▼ key.

3. Press the ▲ key. Factory information is displayed.

A typical example is shown, but information dis-
played varies by model. This information is for fac-

tory use only.

4. Press the ▲ key again to display °C or °F.

Set

Room

INDICATOR

ROOM TEMPERATURE

SETPOINT TEMPERATURE

M14679

M14680

M14681

M14682

M14683

M18426

M18431

M18432

Aux Ht

M18433

M18434

M18435

M18434

M14688