Specifications, Unpacking, Instructions for putting into use – Harbor Freight Tools Pacific Hydrostar Portable Utility Pump 65836 User Manual

Page 8: Operating instructions

Advertising
background image

SKU 65836

For technical questions, please call 1-800-444-3353.

Page 8

SPeciFicationS

Electrical Requirements 115 V~ / 60 Hz / 8.4 A
Pumping Capacity

1500 GPH Max.

Inlet & Outlet Size

1” x 11.5 TPI

(Standard Hose Size)

Pump Lift Capacity

120 Feet

UnPacKing

When unpacking, check to make sure

that the item is intact and undamaged. If

any parts are missing or broken, please

call Harbor Freight Tools at the number

shown on the cover of this manual as soon

as possible.

list of contents

description

Q’ty

Portable Utility Pump

1

Basket Filter

1

inStrUctionS For

PUtting into USe

read the entire imPortant

SaFety inFormation

section at the beginning of this

manual including all text under

subheadings therein before set

up or use of this product.

to PreVent

SerioUS injUry

From accidental

oPeration:

turn the Power Switch of the

tool to its “oFF” position and

unplug the tool from its

electrical outlet before

assembling or making any

adjustments to the tool.

note: For additional information regarding

the parts listed in the following pages,

refer to the Assembly Diagram near

the end of this manual.

assembly

Inlet and outlet hoses (not included)

1.

must be attached to pump prior to

use.
Attach inlet and outlet hoses to Hose

2.

Fittings (3) on Pup Facing (2). Stan-

dard garden hose fitting will work.
Attach the Accessory Basket Filter

3.

included with the Pump to the inlet

end of the inlet hose. The strainer will

prevent foreign material from entering

the pump and damaging or jamming

it.

mounting

Pump should be firmly mounted on a

1.

stabile base prior to use.
The pump and its electrical connec-

2.

tions should be mounted so that they

remain dry. Water may damage the

pump if it enters any electrical com-

ponent.

Functions

This pump is useful for pumping

1.

clean water. Do not use for dirty wa-

ter containing large particulates.

oPerating inStrUctionS

read the entire imPortant

SaFety inFormation

section at the beginning of this

manual including all text under

subheadings therein before set

up or use of this product.

Advertising