Electrical hookup, Wiring numbers and colors, Model osaa-6 – Hill Phoenix OSAA User Manual

Page 17

Advertising
background image

13

ELECTRICAL HOOKUP

DEFROST HEATERS, 208/240 VOLTS

L1

L2

RED

BLUE

EVAPORATOR FANS, 120 VOLT

WIRE NUMBER

COMPONENT

COLOR CODING

BLACK

TEMPERATURE CONTROL, 120 VOLT

LIGHTS, 120 VOLT

DEFROST TERMINATION CONTROL, 120 VOLT

WHITE

3

4

11

12

19

20

21

YELLOW

YELLOW

PURPLE

ORANGE

23

WIRING NUMBERS AND COLORS

EQUIPMENT GROUNDING CONDUCTOR

GREEN

-

BLACK

WHITE

ANTI-CONDENSATE HEATERS, 120 VOLT

13

14

WHITE

BLACK

5 13/16 in [14.7 cm]

38 5/16 in

[97.3 cm]

49 1/16 in

[124.6 cm]

34 1/2 in

[87.6 cm]

ELECTRICAL

JUNCTION BOX

(STANDARD)

25 9/16 in [64.9 cm]

28 1/16 in [71.2 cm]

FRONT OF CASE

1 1/2 in [3.8 cm]

{END}

21 1/2 in

[54.6 cm]

**

NOTES:

** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS

C

L

72 in [182.9 cm] {6' case}

MODEL OSAA-6’

REAR SILL

BALLAST
LOCATION

REMOVABLE
COVER

BALLAST
LOCATION

Electrical hookups for the OSAA are made

to a junction box located underneath the case on
the bottom left hand front. The light ballasts for
the case are located under the rear sill behind a
removable access cover as shown below.

For case-to-case wiring, run “green-

field”, or other conduit, between junction
boxes. When connecting to the junction box
field connections should be made on the
right hand side of the box to allow more room
inside for wire connecting.

Advertising